The Pre-filter (part #AWFP2424)
The Dust Filter (part #AWFD2424)
The HEPA Filter (part #AWHF0411)
Symptoms
Possible Cause Suggested Solution
Unit will not start
Faulty power supply
Return or supply grill block ed
Blown fuse
Unit not plugged in
Check breaker box
Remove obstruction
Replace fuse
Plug in unit
Insufficient air flow
Obstruction in system
Clogged filters
Remove obstruction
Replace filters
Excessive airflow
Filters not in place
Install filt
ers
AR 2000 and AR 4000
Dual Purpose Air Rhino Units
and
Filter Change Directions
Filter Replacement Directions
Should be changed daily in an industrial application and as needed in a light applicat
i
Unsnap the door latches and open the door.
Remove the used pre-filter and replace with a new pre-filter
-
Close the door and relatch the snaps
See diagram on reverse
Should be changed when the gauge reads: and above 1.7 or when the light comes on depending
on how unit is equiped.
Unsnap the door latches and open the door.
Remove the prefilter, wire-frame filter and carbon filter if supplied.
-
Loosen wing nuts and remove the HEPA filter
Reverse the above procedure to replace the HEPA filter
Dispose of used filters according to local environmental regulations
See diagram on reverse
Should be changed every 2 to 3 days in an industrial application and as needed in a lig
h
application
Unsnap the door latches and open the door.
Remove the used Dust filter and replace with a new pre-f i lte r
See diagram on reverse
Warning: Before opening unit for any reason unplug the unit
For maximum performance it is very important to change filters as
specified in these directions
Trouble Shooting Guide
The Carbon Filter (part #AWCF0500)
Should be changed as required - Life of the carbon depends on what and how much product
it is adsorbing. The only way to know carbon has reached its capacity is when it starts to off gas.
Record the first time it starts to off gas and schedule to change the carbon one or two months
before. You have created your schedule.
Canister Only
Unsnap the door latches and open the door.
Remove the pre-filter and the wire-frame filter
Loosen wing nuts and remove the HEPA filter
Reverse the above procedure to replace the HEPA filter
Dispose of used filters according to local environmental regulations
Note: May be equiped with AWCF0314 carbon filter.
Close the door and relatch the snaps
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Dual Purpose Air Rhino Units

The Pre-filter (part #AWFP2424)The Dust Filter (part #AWFD2424)The HEPA Filter (part #AWHF0411)SymptomsPossible Cause Suggested SolutionUnit will not

Page 2

1) Open the door and pull outthe pre-filtersDust filterA WFD2424W hite Pr e-filterAWFP24242) Untight the 4 wing-nuts3) Pull out the HEPA or Carbon fil

Modèles reliés AR 2000

Commentaires sur ces manuels

Pas de commentaire